Gap Filler Detail

1962 – National Archives of Canada


10-36-80/5 (DCEP)

MEMORANDUM

25 Sep 62

DArchO (thru DCEC)

Redrawing Std Radar Bldg and
Power & Accommodation Bldg
Gap Filler Radar Stations, Various

The original drawings for the Std Radar Building and Power & Accommodation Building consist of the following sheets:

S-13-1104
-1
Plans, Elevations, Sections (on paper)
-2Foundations, Sections, Details (on paper)
-3Erection Details of Liner Panels (on paper)
-4Ventilation System (on paper)
-5Electrical Layout & Details (on linen)
-6Electrical Details (on linen)
-7F A Protectowire System (on linen)
-8Covered Entrance, Plan, Elevation & Details (on paper)
S-22-1048
-1
Plans, Elevations, Sections, Plumbing (on paper)
-2Erection Details of Liner Panels (on paper)
-3Electrical Layout & Details (on sensitized film)
-4Electrical Details (on sensitized film)
-5APU Plan & Details (on paper)
-6F A Protectowire Sytem (on sensitized film)

With forty five (45) stations involved, approximately 3,500 blueprints of each sheet have had to be printed and as a result the original drawings are in very poor condition.

It is requested that those drawings on paper be redrawn in ink on line, incorporating changes which have been authorized by letters, sketches or addenda to DCL.

The actual redrawing should be discussed with the Project Officer (CEP-3-3) before the work is commenced.

(MC Hyslop) W/C
DCEP
2-5777